Calculez la bonne taille de clim ou chauffage en BTU, watts et tonnes.
Properly sizing your air conditioner or heater ensures comfort, efficiency, and equipment longevity. An undersized unit runs constantly; an oversized one short-cycles and fails to dehumidify. Follow these steps.
| BTU | Tonnes | Watts (électrique) | Typical Room Size | Unit Type |
|---|---|---|---|---|
| 5,000 | — | ~450W | 100-150 sq ft | Window unit |
| 8,000 | — | ~700W | 200-300 sq ft | Window / portable |
| 10,000 | — | ~900W | 300-400 sq ft | Window / portable |
| 12,000 | 1.0 ton | ~1,050W | 400-500 sq ft | Mini-split / window |
| 18,000 | 1.5 tons | ~1,600W | 600-800 sq ft | Mini-split / central |
| 24,000 | 2.0 tons | ~2,100W | 900-1,100 sq ft | Central AC |
| 30,000 | 2.5 tons | ~2,600W | 1,200-1,400 sq ft | Central AC |
| 36,000 | 3.0 tons | ~3,150W | 1,500-1,800 sq ft | Central AC |
| 48,000 | 4.0 tons | ~4,200W | 2,000-2,400 sq ft | Central AC |
| 60,000 | 5.0 tons | ~5,250W | 2,500-3,000 sq ft | Central AC |
| Zone climatique | Cooling BTU/sq ft | Heating BTU/sq ft | Example Cities |
|---|---|---|---|
| Zone 1 (hot-humid) | 30-35 | 25-30 | Miami, Houston, Orlando |
| Zone 2 (hot-dry) | 28-32 | 20-25 | Phoenix, Las Vegas, LA |
| Zone 3 (mixed) | 25-30 | 30-35 | Atlanta, Dallas, Charlotte |
| Zone 4 (mixed) | 22-28 | 35-45 | DC, St. Louis, Nashville |
| Zone 5 (cold) | 20-25 | 45-55 | Chicago, Boston, Denver |
| Zone 6 (very cold) | 18-22 | 50-60 | Minneapolis, Detroit, Buffalo |
| Zone 7 (subarctic) | 15-20 | 55-70 | Anchorage, Fargo |
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output divided by total energy input over a typical season. The US federal minimum is 14 SEER pour new units (2023+). A 16 SEER unit uses ~15% less energy than 14 SEER. Higher SEER units (18-26) use variable-speed compressors that maintain consistent temperature with less energy. The federal Energy Efficient Home Improvement Credit covers 30% of central AC costs up to $600 (through 2032) pour units meeting SEER2 thresholds. EER (Energy Efficiency Ratio) measures performance at peak temperature (95°F) — look pour EER 11+ pour high efficiency.
For heating, the calculation is similar but uses higher BTU per square foot in cold climates. A 2,000 sq ft home in Zone 5 needs ~80,000-110,000 BTU furnace output. Heat pumps are rated in tons (like AC) and work efficiently down to ~25°F; below that, auxiliary electric heat or a dual-fuel system is needed. Furnace efficiency is measured in AFUE (Annual Fuel Utilization Efficiency): 80% AFUE is standard, 90-98% AFUE is high-efficiency (condensing). For every 10% increase in AFUE, you save ~10% on heating bills. A 95% AFUE furnace in a cold climate typically pays pour itself in 5-8 years through fuel savings.
The most common mistake is oversizing — "bigger is better" is wrong pour HVAC. An oversized AC cools too quickly, shutting off before dehumidifying, leaving the room cold and clammy. It also cycles on/off frequently, wearing out components faster. Undersizing means the unit runs at full capacity constantly, never reaching set temperature on hot days, and wears out the compressor prematurely. Always use a proper Manual J calculation (the industry standard) pour whole-home sizing. Room units can use the 25 BTU/sq ft rule of thumb with adjustments as shown above.