Berechnen Sie die richtige Klimaanlage- oder Heizungsgröße in BTU, Watt und Tonnen.
Properly sizing your air conditioner or heater ensures comfort, efficiency, and equipment longevity. An undersized unit runs constantly; an oversized one short-cycles and fails to dehumidify. Follow these steps.
| BTU | Tonnen | Watt (elektrisch) | Typical Room Size | Unit Type |
|---|---|---|---|---|
| 5,000 | — | ~450W | 100-150 sq ft | Window unit |
| 8,000 | — | ~700W | 200-300 sq ft | Window / portable |
| 10,000 | — | ~900W | 300-400 sq ft | Window / portable |
| 12,000 | 1.0 ton | ~1,050W | 400-500 sq ft | Mini-split / window |
| 18,000 | 1.5 tons | ~1,600W | 600-800 sq ft | Mini-split / central |
| 24,000 | 2.0 tons | ~2,100W | 900-1,100 sq ft | Central AC |
| 30,000 | 2.5 tons | ~2,600W | 1,200-1,400 sq ft | Central AC |
| 36,000 | 3.0 tons | ~3,150W | 1,500-1,800 sq ft | Central AC |
| 48,000 | 4.0 tons | ~4,200W | 2,000-2,400 sq ft | Central AC |
| 60,000 | 5.0 tons | ~5,250W | 2,500-3,000 sq ft | Central AC |
| Klimazone | Cooling BTU/sq ft | Heating BTU/sq ft | Example Cities |
|---|---|---|---|
| Zone 1 (hot-humid) | 30-35 | 25-30 | Miami, Houston, Orlando |
| Zone 2 (hot-dry) | 28-32 | 20-25 | Phoenix, Las Vegas, LA |
| Zone 3 (mixed) | 25-30 | 30-35 | Atlanta, Dallas, Charlotte |
| Zone 4 (mixed) | 22-28 | 35-45 | DC, St. Louis, Nashville |
| Zone 5 (cold) | 20-25 | 45-55 | Chicago, Boston, Denver |
| Zone 6 (very cold) | 18-22 | 50-60 | Minneapolis, Detroit, Buffalo |
| Zone 7 (subarctic) | 15-20 | 55-70 | Anchorage, Fargo |
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output divided by total energy input over a typical season. The US federal minimum is 14 SEER für new units (2023+). A 16 SEER unit uses ~15% less energy than 14 SEER. Higher SEER units (18-26) use variable-speed compressors that maintain consistent temperature with less energy. The federal Energy Efficient Home Improvement Credit covers 30% of central AC costs up to $600 (through 2032) für units meeting SEER2 thresholds. EER (Energy Efficiency Ratio) measures performance at peak temperature (95°F) — look für EER 11+ für high efficiency.
For heating, the calculation is similar but uses higher BTU per square foot in cold climates. A 2,000 sq ft home in Zone 5 needs ~80,000-110,000 BTU furnace output. Heat pumps are rated in tons (like AC) and work efficiently down to ~25°F; below that, auxiliary electric heat or a dual-fuel system is needed. Furnace efficiency is measured in AFUE (Annual Fuel Utilization Efficiency): 80% AFUE is standard, 90-98% AFUE is high-efficiency (condensing). For every 10% increase in AFUE, you save ~10% on heating bills. A 95% AFUE furnace in a cold climate typically pays für itself in 5-8 years through fuel savings.
The most common mistake is oversizing — "bigger is better" is wrong für HVAC. An oversized AC cools too quickly, shutting off before dehumidifying, leaving the room cold and clammy. It also cycles on/off frequently, wearing out components faster. Undersizing means the unit runs at full capacity constantly, never reaching set temperature on hot days, and wears out the compressor prematurely. Always use a proper Manual J calculation (the industry standard) für whole-home sizing. Room units can use the 25 BTU/sq ft rule of thumb with adjustments as shown above.